ACME HQDemo work items and pages, made up for Emargen's demo. Not a real company.
Engineering / ENG-1512

Okta: when the depot attribute is empty, use the person's home depot and log it

Project
Engineering
Type
Story
Status
Done Done
Priority
Medium
Organization
Vossberg Logistik
Reporter
Lena Fischer <lena.fischer@acme-hq.example>
Assignee
Marek Nowak <marek.nowak@acme-hq.example>
Labels
vossbergokta
Components
identity-service
Fix versions
identity-service 2026.07.02
Sprint
Sprint 45
Story points
2
Created
29 Jun 2026, 09:00 UTC
Updated
2 Jul 2026, 13:40 UTC
Resolved
2 Jul 2026, 13:40 UTC

Description

38 people at Billbrook couldn't sign in after their depot switched: their Okta profiles have no depot attribute (SUP-990). Same family as SUP-958.

Refusing them helps nobody: they work at Billbrook, and their account in ACME says so.

Acceptance criteria

Linked issues

Comments (1)

Marek Nowak ยท 2 Jul 2026, 13:40 UTC

Deployed. Billbrook back on Okta at 14:00; 38 sign-ins went through this afternoon with the log line.