Brakeline: 14 new starters at Leeds can't sign in after the switch
Description
14 new drivers at Leeds get "No account found for this sign-in" after the Microsoft page. They start today. Everyone else at Leeds is fine since the switch.
Linked issues
- relates to SUP-388 Brakeline rollout of single sign-on Done
- relates to SUP-781 Brakeline: new Hull driver gets 'No account found' after Microsoft sign-in Done
Comments (4)
Sam Whitfield · 7 Mar 2026, 06:40 UTC
Shift lead has them on the paper list at the gate for now. Priya's on it.
Priya Nair · 7 Mar 2026, 07:58 UTC
All 14 added, they're in. HR sent the list on Friday night.
Ana Ruiz · 7 Mar 2026, 08:20 UTC
Thanks both. Closing; the checklist will ask for new starters' accounts before the weekend.
Hi Sam, those 14 don't have accounts in the portal yet. Accounts aren't created from Entra ID: a person needs an account before their first single sign-on.
Priya's team can add them under People → Add person, with the same email as in Entra ID. They can sign in straight after.